| Requirements for Infloor Heating Systems
Quote |
| |
Print and submit this information with
all the required information below for the most accurate quote. Any item not completed could delay our response.
PLEASE do not fax plans to us as they are difficult to work with.
|
|
Fuel Type ____Natural Gas ____Propane
____Electric |
 |
Altitude: Project Altitude _________________ |
 |
How many zones? ____________________ |
 |
(Zone is an area that is controlled by a thermostat; this can be a
few rooms or just one room ** Please provide a list of which
rooms are included in which zone
Zone1____________________________________________________________
Zone2____________________________________________________________
Zone3____________________________________________________________
Zone4____________________________________________________________
Zone5____________________________________________________________
Zone6____________________________________________________________
Zone7____________________________________________________________
Zone8____________________________________________________________
Zone9____________________________________________________________
Zone10___________________________________________________________ |
|
How many square feet of a concrete application do you have?
_____________ (concrete application is installing
tubing in a concrete slab) |
|
How many square feet of the application are
above slab
level or to be installed on top of a sub floor or underneath a sub
floor |
|
A |
_______ Staple down
systems are encased in 1 1/4" of
gypcrete or lightweight concrete. |
|
B |
_______ Staple up
system with the use of emission plates. Emission plates are attached
underneath the sub floor using an aluminum plate that is 4"wide and
spaced 8" on center extending the full length of the joist bay. (R-Value of insulation under plates must be R-19) |
|
C |
_______ Staple up
system are systems that are attached underneath the sub floor with
tubing spaced 8" on center extending the full length of the joist
bay. ( This is the least efficient way to install radiant floor) (R-Value of insulation must be R-19 foil faced) |
| D |
_______ Infloorboard
systems are installed on top of sub floor and only raise the floor
height 5/8". |
|
Please select:
whether you would like to heat your domestic water with your boiler. |
| |
_______ Heat Domestic with boiler |
| |
_______ Provide my own water heater |
|
Please select:
|
| |
_______ Heated Garage |
| |
_______ Non Heated Garage |
|
What type of heat plant would you like? |
|
A |
_______ Cast iron
boiler. Cast iron boilers will provide years of trouble free
operation with very little
maintenance with an 8% to 87% operating efficiency with a 25-year
warranty on the heat exchanger only. |
|
B |
_______ Hi Efficiency
condensing boiler. Stainless steel condensing boiler will
provide the most efficiency in operating cost but requires yearly
maintenance and has a 12-year warranty on heat exchanger only, these
boilers operate with a 92% to 97% operating efficiency. |
| C |
_______ Instantaneous
water heater. Instantaneous water heater will provide heat
for small projects with an operating efficiency of 8% to 85% and a 3
year warranty when used in heating applications. |
 |
Please provide a
complete set of drawings that are to scale. |
|
Please submit the window and door schedule with the prints (or have dimensions on
the drawing).
|
|
Please provide the print sheet that lists or shows the ceiling
heights of each individual room.
|
|
Please provide the window and door schedule with the prints (or have
the dimensions on the drawings.) |
|
Please provide a list of the finished floor coverings for each room,
if possible. (carpet, hardwood, tile, concrete |
|
Please submit the anticipated R-Value for the following:
|
| |
_______ Exterior Doors |
| |
_______ Exterior Windows |
| |
_______ Exterior Walls |
| |
_______ Roof |
| |
_______ Under
slab |
| |
_______ Under Sub Floor |
| This sheet is for preliminary bidding
purposes only. A certified designer should perform a heat loss
calculation to assure the proper operation of the radiant floor
system. | |
| | |
| Please allow 7 to 14 working days for the quote of your heat system. Please submit the
information to the following address:
|
Infloor Sales & Services Southwest PO Box 4945 503 Gregg Drive Buena Vista CO 81211
800-615-6901 |